| 1 |
Guideline Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. free! 2008
Morgenthaler TI, Aurora RN, Brown T, Zak R, Alessi C, Boehlecke B, Chesson AL, Friedman L, Kapur V, Maganti R, Owens J, Pancer J, Swick TJ, Anonymous00064, Anonymous00065. · Mayo Clinic, Rochester MN, USA. · Sleep. · Pubmed #18220088 links to free full text
Abstract: These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.
|
| 2 |
Article Excessive daytime sleepiness and sleep complaints among children with epilepsy. 2006
Maganti R, Hausman N, Koehn M, Sandok E, Glurich I, Mukesh BN. · Department of Neurology, Barrows Neurological Institute, Phoenix, AZ, USA. · Epilepsy Behav. · Pubmed #16352471 No free full text.
Abstract: OBJECTIVE: Excessive daytime sleepiness (EDS) and sleep complaints are common among adults with epilepsy. We hypothesized that children with epilepsy have worse daytime sleepiness compared with controls. METHODS: Children with and without epilepsy between ages 8 and 18 were recruited for the study. Parents and children were asked to fill out the Pediatric Sleep Questionnaire (PSQ) and Pediatric Daytime Sleepiness Scale (PDSS), respectively. The Mann-Whitney U test was used for group comparisons, with the Fischer exact or chi2 test for categorical variables. Regression analysis was used to identify predictors of EDS. RESULTS: Twenty-six patients and matched controls were recruited for the study. Parents of children with epilepsy more often reported EDS (P < 0.001), symptoms of sleep-disordered breathing (P < 0.001), and parasomnias (P < 0.001) compared with controls. On the PDSS, children with epilepsy reported worse daytime sleepiness scores compared with controls (15.48 +/- 6.4 vs 11.88 +/- 5.25, P = 0.037). Based on conditional logistic regression modeling, symptoms of excessive daytime sleepiness [corrected] (OR = 15.3, 95% CI = 1.4-166.6) and parasomnias (OR = 12.4, 95% CI = 1.01-151.6) were significantly associated with having epilepsy when adjusted for duration of nightime sleep. Further, 10 children (38.5%) with epilepsy reported positive sleep-disordered breathing, whereas no one in the control group reported SDB (P < 0.001) [corrected] Epilepsy syndrome, anticonvulsants used, and presence or absence of seizure freedom, however, were not significant predictors of EDS among patients. CONCLUSIONS: Daytime sleepiness appears to be common in children with epilepsy, and may be due to underlying sleep disorders. Further confirmatory studies are needed using screening questionnaires and formal sleep studies to systematically study the prevalence of sleep complaints and role of sleep disorders in these patients.
|
|
|