Sleep Apnea Syndromes: Friedman L

 Topic:  
Hints · Remembered Topics    
  Start Here  Overview  World Articles  Find Experts  Books & DVDs  Help 
 
Column View Map 5 Articles   Help
A digest of articles written 1999 and later, on the topic "Sleep Apnea Syndromes," originating from Planet Earth —» Friedman L.  Display:  All Citations ·  All Abstracts
1 Guideline Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. free! 2008

Morgenthaler TI, Aurora RN, Brown T, Zak R, Alessi C, Boehlecke B, Chesson AL, Friedman L, Kapur V, Maganti R, Owens J, Pancer J, Swick TJ, Anonymous00064, Anonymous00065. · Mayo Clinic, Rochester MN, USA. · Sleep. · Pubmed #18220088 links to  free full text

Abstract: These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.

2 Guideline Practice parameters for the medical therapy of obstructive sleep apnea. 2006

Morgenthaler TI, Kapen S, Lee-Chiong T, Alessi C, Boehlecke B, Brown T, Coleman J, Friedman L, Kapur V, Owens J, Pancer J, Swick T, Anonymous00044, Anonymous00045. · Sleep Disorders Center, Pulm Crit Care Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA. · Sleep. · Pubmed #16944671 No free full text.

Abstract: Therapies for obstructive sleep apnea other than positive airway pressure, oral appliances, and surgical modifications of the upper airway are reviewed in this practice parameter. Several of these therapies such as weight loss and positional therapy hold some promise. Others, such as serotonergic agents, may gain credibility in the future but lack well-designed clinical trials. No practice parameters could be developed for a number of possible therapeutic modalities that had little or no evidence-based data on which to form a conclusion. The role of an organized, targeted weight-loss program either as a single therapy or as a supplement to PAP needs to be clarified. Although bariatric surgery is increasingly performed for refractory medically complicated obesity, its long-term effectiveness in treatment of obstructive sleep apnea in morbidly obese patients is not yet demonstrated. Positional therapy, or methods for preventing sleep in the supine position, has probably been underutilized due to lack of easily measured predictive factors and randomized controlled trials.

3 Guideline Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. 2006

Kushida CA, Littner MR, Hirshkowitz M, Morgenthaler TI, Alessi CA, Bailey D, Boehlecke B, Brown TM, Coleman J, Friedman L, Kapen S, Kapur VK, Kramer M, Lee-Chiong T, Owens J, Pancer JP, Swick TJ, Wise MS, Anonymous00039. · Stanford University Center of Excellence for Sleep Disorders, Stanford, CA, USA. · Sleep. · Pubmed #16553024 No free full text.

Abstract: Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBD) including obstructive sleep apnea (OSA). Currently, PAP devices come in three forms: (1) continuous positive airway pressure (CPAP), (2) bilevel positive airway pressure (BPAP), and (3) automatic self-adjusting positive airway pressure (APAP). After a patient is diagnosed with OSA, the current standard of practice involves performing full, attended polysomnography during which positive pressure is adjusted to determine optimal pressure for maintaining airway patency. This titration is used to find a fixed single pressure for subsequent nightly usage. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine reviewed the available literature. Based on this review, the Standards of Practice Committee developed these practice parameters as a guideline for using CPAP and BPAP appropriately (an earlier review and practice parameters for APAP was published in 2002). Major conclusions and current recommendations are as follows: 1) A diagnosis of OSA must be established by an acceptable method. 2) CPAP is effective for treating OSA. 3) Full-night, attended studies performed in the laboratory are the preferred approach for titration to determine optimal pressure; however, split-night, diagnostic-titration studies are usually adequate. 4) CPAP usage should be monitored objectively to help assure utilization. 5) Initial CPAP follow-up is recommended during the first few weeks to establish utilization pattern and provide remediation if needed. 6) Longer-term follow-up is recommended yearly or as needed to address mask, machine, or usage problems. 7) Heated humidification and a systematic educational program are recommended to improve CPAP utilization. 8) Some functional outcomes such as subjective sleepiness improve with positive pressure treatment in patients with OSA. 9) CPAP and BPAP therapy are safe; side effects and adverse events are mainly minor and reversible. 10) BPAP may be useful in treating some forms of restrictive lung disease or hypoventilation syndromes associated with hypercapnia.

4 Guideline Practice parameters for the treatment of snoring and Obstructive Sleep Apnea with oral appliances: an update for 2005. 2006

Kushida CA, Morgenthaler TI, Littner MR, Alessi CA, Bailey D, Coleman J, Friedman L, Hirshkowitz M, Kapen S, Kramer M, Lee-Chiong T, Owens J, Pancer JP, Anonymous00038. · Stanford University Center of Excellence for Sleep Disorders, CA, USA. · Sleep. · Pubmed #16494092 No free full text.

Abstract: These practice parameters are an update of the previously published recommendations regarding use of oral appliances in the treatment of snoring and Obstructive Sleep Apnea (OSA). Oral appliances (OAs) are indicated for use in patients with mild to moderate OSA who prefer them to continuous positive airway pressure (CPAP) therapy, or who do not respond to, are not appropriate candidates for, or who fail treatment attempts with CPAP. Until there is higher quality evidence to suggest efficacy, CPAP is indicated whenever possible for patients with severe OSA before considering OAs. Oral appliances should be fitted by qualified dental personnel who are trained and experienced in the overall care of oral health, the temporomandibular joint, dental occlusion and associated oral structures. Follow-up polysomnography or an attended cardiorespiratory (Type 3) sleep study is needed to verify efficacy, and may be needed when symptoms of OSA worsen or recur. Patients with OSA who are treated with oral appliances should return for follow-up office visits with the dental specialist at regular intervals to monitor patient adherence, evaluate device deterioration or maladjustment, and to evaluate the health of the oral structures and integrity of the occlusion. Regular follow up is also needed to assess the patient for signs and symptoms of worsening OSA. Research to define patient characteristics more clearly for OA acceptance, success, and adherence is needed.

5 Guideline Practice parameters for the indications for polysomnography and related procedures: an update for 2005. 2005

Kushida CA, Littner MR, Morgenthaler T, Alessi CA, Bailey D, Coleman J, Friedman L, Hirshkowitz M, Kapen S, Kramer M, Lee-Chiong T, Loube DL, Owens J, Pancer JP, Wise M. · Stanford University Center of Excellence for Sleep Disorders, Stanford, CA, USA. · Sleep. · Pubmed #16171294 No free full text.

Abstract: These practice parameters are an update of the previously-published recommendations regarding the indications for polysomnography and related procedures in the diagnosis of sleep disorders. Diagnostic categories include the following: sleep related breathing disorders, other respiratory disorders, narcolepsy, parasomnias, sleep related seizure disorders, restless legs syndrome, periodic limb movement sleep disorder, depression with insomnia, and circadian rhythm sleep disorders. Polysomnography is routinely indicated for the diagnosis of sleep related breathing disorders; for continuous positive airway pressure (CPAP) titration in patients with sleep related breathing disorders; for the assessment of treatment results in some cases; with a multiple sleep latency test in the evaluation of suspected narcolepsy; in evaluating sleep related behaviors that are violent or otherwise potentially injurious to the patient or others; and in certain atypical or unusual parasomnias. Polysomnography may be indicated in patients with neuromuscular disorders and sleep related symptoms; to assist in the diagnosis of paroxysmal arousals or other sleep disruptions thought to be seizure related; in a presumed parasomnia or sleep related seizure disorder that does not respond to conventional therapy; or when there is a strong clinical suspicion of periodic limb movement sleep disorder. Polysomnography is not routinely indicated to diagnose chronic lung disease; in cases of typical, uncomplicated, and noninjurious parasomnias when the diagnosis is clearly delineated; for patients with seizures who have no specific complaints consistent with a sleep disorder; to diagnose or treat restless legs syndrome; for the diagnosis of circadian rhythm sleep disorders; or to establish a diagnosis of depression.