| 1 |
Guideline Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. free! 2008
Morgenthaler TI, Aurora RN, Brown T, Zak R, Alessi C, Boehlecke B, Chesson AL, Friedman L, Kapur V, Maganti R, Owens J, Pancer J, Swick TJ, Anonymous00064, Anonymous00065. · Mayo Clinic, Rochester MN, USA. · Sleep. · Pubmed #18220088 links to free full text
Abstract: These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.
|
| 2 |
Guideline Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine. free! 2007
Collop NA, Anderson WM, Boehlecke B, Claman D, Goldberg R, Gottlieb DJ, Hudgel D, Sateia M, Schwab R, Anonymous00275. · Division of Pulmonary and Critical Care Medicine, Johns Hopkins University, Baltimore, MD 21205, USA. · J Clin Sleep Med. · Pubmed #18198809 links to free full text
Abstract: Based on a review of literature and consensus, the Portable Monitoring Task Force of the American Academy of Sleep Medicine (AASM) makes the following recommendations: unattended portable monitoring (PM) for the diagnosis of obstructive sleep apnea (OSA) should be performed only in conjunction with a comprehensive sleep evaluation. Clinical sleep evaluations using PM must be supervised by a practitioner with board certification in sleep medicine or an individual who fulfills the eligibility criteria for the sleep medicine certification examination. PM may be used as an alternative to polysomnography (PSG) for the diagnosis of OSA in patients with a high pretest probability of moderate to severe OSA. PM is not appropriate for the diagnosis of OSA in patients with significant comorbid medical conditions that may degrade the accuracy of PM. PM is not appropriate for the diagnostic evaluation of patients suspected of having comorbid sleep disorders. PM is not appropriate for general screening of asymptomatic populations. PM may be indicated for the diagnosis of OSA in patients for whom in-laboratory PSG is not possible by virtue of immobility, safety, or critical illness. PM may also be indicated to monitor the response to non-CPAP treatments for sleep apnea. At a minimum, PM must record airflow, respiratory effort, and blood oxygenation. The airflow, effort, and oximetric biosensors conventionally used for in-laboratory PSG should be used in PM. The Task Force recommends that PM testing be performed under the auspices of an AASM-accredited comprehensive sleep medicine program with written policies and procedures. An experienced sleep technologist/technician must apply the sensors or directly educate patients in sensor application. The PM device must allow for display of raw data with the capability of manual scoring or editing of automated scoring by a qualified sleep technician/technologist. A board certified sleep specialist, or an individual who fulfills the eligibility criteria for the sleep medicine certification examination, must review the raw data from PM using scoring criteria consistent with current published AASM standards. Under the conditions specified above, PM may be used for unattended studies in the patient's home. Afollow-up visit to review test results should be performed for all patients undergoing PM. Negative or technically inadequate PM tests in patients with a high pretest probability of moderate to severe OSA should prompt in-laboratory polysomnography.
|
| 3 |
Guideline Practice parameters for the medical therapy of obstructive sleep apnea. 2006
Morgenthaler TI, Kapen S, Lee-Chiong T, Alessi C, Boehlecke B, Brown T, Coleman J, Friedman L, Kapur V, Owens J, Pancer J, Swick T, Anonymous00044, Anonymous00045. · Sleep Disorders Center, Pulm Crit Care Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA. · Sleep. · Pubmed #16944671 No free full text.
Abstract: Therapies for obstructive sleep apnea other than positive airway pressure, oral appliances, and surgical modifications of the upper airway are reviewed in this practice parameter. Several of these therapies such as weight loss and positional therapy hold some promise. Others, such as serotonergic agents, may gain credibility in the future but lack well-designed clinical trials. No practice parameters could be developed for a number of possible therapeutic modalities that had little or no evidence-based data on which to form a conclusion. The role of an organized, targeted weight-loss program either as a single therapy or as a supplement to PAP needs to be clarified. Although bariatric surgery is increasingly performed for refractory medically complicated obesity, its long-term effectiveness in treatment of obstructive sleep apnea in morbidly obese patients is not yet demonstrated. Positional therapy, or methods for preventing sleep in the supine position, has probably been underutilized due to lack of easily measured predictive factors and randomized controlled trials.
|
| 4 |
Guideline Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. 2006
Kushida CA, Littner MR, Hirshkowitz M, Morgenthaler TI, Alessi CA, Bailey D, Boehlecke B, Brown TM, Coleman J, Friedman L, Kapen S, Kapur VK, Kramer M, Lee-Chiong T, Owens J, Pancer JP, Swick TJ, Wise MS, Anonymous00039. · Stanford University Center of Excellence for Sleep Disorders, Stanford, CA, USA. · Sleep. · Pubmed #16553024 No free full text.
Abstract: Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBD) including obstructive sleep apnea (OSA). Currently, PAP devices come in three forms: (1) continuous positive airway pressure (CPAP), (2) bilevel positive airway pressure (BPAP), and (3) automatic self-adjusting positive airway pressure (APAP). After a patient is diagnosed with OSA, the current standard of practice involves performing full, attended polysomnography during which positive pressure is adjusted to determine optimal pressure for maintaining airway patency. This titration is used to find a fixed single pressure for subsequent nightly usage. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine reviewed the available literature. Based on this review, the Standards of Practice Committee developed these practice parameters as a guideline for using CPAP and BPAP appropriately (an earlier review and practice parameters for APAP was published in 2002). Major conclusions and current recommendations are as follows: 1) A diagnosis of OSA must be established by an acceptable method. 2) CPAP is effective for treating OSA. 3) Full-night, attended studies performed in the laboratory are the preferred approach for titration to determine optimal pressure; however, split-night, diagnostic-titration studies are usually adequate. 4) CPAP usage should be monitored objectively to help assure utilization. 5) Initial CPAP follow-up is recommended during the first few weeks to establish utilization pattern and provide remediation if needed. 6) Longer-term follow-up is recommended yearly or as needed to address mask, machine, or usage problems. 7) Heated humidification and a systematic educational program are recommended to improve CPAP utilization. 8) Some functional outcomes such as subjective sleepiness improve with positive pressure treatment in patients with OSA. 9) CPAP and BPAP therapy are safe; side effects and adverse events are mainly minor and reversible. 10) BPAP may be useful in treating some forms of restrictive lung disease or hypoventilation syndromes associated with hypercapnia.
|
| 5 |
Review Controversies in monitoring and testing for sleep-disordered breathing. 2001
Boehlecke B. · University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7310, USA. · Curr Opin Pulm Med. · Pubmed #11706311 No free full text.
Abstract: Despite significant advances in the understanding of the pathophysiology of the obstructive sleep apnea syndrome, the best index to classify the severity of sleep-disordered breathing has not been established. The use of new measurement techniques suggests that subtle changes in airflow not detected by conventional thermal sensing devices may signal events associated with significant sleep disruption. Recurrent increased respiratory efforts without discernable changes in airflow, which are currently reliably detectable only by invasive means, also may be important. However, it is still uncertain which events should be considered clinically significant, and the correlation of the frequency of various types of respiratory events with long term physiologic consequences is not clear. Outpatient screening with multichannel portable devices or pulse oximetry has important limitations. However, in combination with the clinical pretest probability of significant sleep-disordered breathing, such screening may correctly classify a large proportion of patients. Combining a partial night diagnostic sleep study with a therapeutic titration of continuous positive airway pressure seems to provide adequate information for appropriate management of many patients with obstructive sleep apnea and reduces time between presentation and initiation of treatment.
|
|
|