| 1 |
Guideline Meeting report ESC forum on drug eluting stents, European Heart House, Nice, 27-28 September 2007. 2009
Daemen J, Simoons ML, Wijns W, Bagust A, Bos G, Bowen JM, Braunwald E, Camenzind E, Chevaliers B, DiMario C, Fajadeto J, Gitt A, Guagliumi G, Hillege HL, James S, Jüni P, Kastrati A, Kloth S, Kristensen SD, Krucoff M, Legrand V, Pfisterer M, Rothman M, Serruys PW, Silber S, Steg PG, Tariah I, Wallentin L, Windecker SW, Aimonetti A, Allocco D, Berenger M, Boam A, Calle JP, Campo G, Carlier S, de Schepper J, Di Bisceglie G, Dobbels H, Farb A, Ghislain JC, Hellbardt S, ten Hoedt R, Isaia C, de Jong P, Lekehal M, LeNarz L, Mhullain FN, Nagai H, Patteet A, Paunovic D, Potgieter A, Purdy I, Raveau-Landon C, Ternstrom S, Van Wuytswinkel J, Waliszewski M, Anonymous00071. · Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands. · EuroIntervention. · Pubmed #19284063 No free full text.
This publication has no abstract.
|
| 2 |
Editorial The drug-eluting stent saga. 2009
Windecker S, Jüni P. · No affiliation provided · Circulation. · Pubmed #19204314 No free full text.
This publication has no abstract.
|
| 3 |
Review A meta-analysis of 16 randomized trials of sirolimus-eluting stents versus paclitaxel-eluting stents in patients with coronary artery disease. 2007
Schömig A, Dibra A, Windecker S, Mehilli J, Suárez de Lezo J, Kaiser C, Park SJ, Goy JJ, Lee JH, Di Lorenzo E, Wu J, Jüni P, Pfisterer ME, Meier B, Kastrati A. · Deutsches Herzzentrum, Technische Universität, Munich, Germany. · J Am Coll Cardiol. · Pubmed #17903638 No free full text.
Abstract: OBJECTIVES: Our purpose was to make a synthesis of the available evidence on the relative efficacy and safety of 2 drug-eluting stents (DES)--sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES)--in patients with coronary artery disease. BACKGROUND: It is not known whether there are differences in late outcomes between the 2 most commonly used DES: SES and PES. METHODS: Sixteen randomized trials of SES versus PES with a total number of 8,695 patients were included in this meta-analysis. A full set of individual outcome data from 5,562 patients was also available. Mean follow-up period ranged from 9 to 37 months. The primary efficacy end point was the need for reintervention (target lesion revascularization). The primary safety end point was stent thrombosis. Secondary end points were death and recurrent myocardial infarction (MI). RESULTS: No significant heterogeneity was found across trials. Compared with PES, SES significantly reduced the risk of reintervention (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.63 to 0.87, p < 0.001) and stent thrombosis (HR 0.66; 95% CI 0.46 to 0.94, p = 0.02) without significantly impacting on the risk of death (HR 0.92; 95% CI 0.74 to 1.13, p = 0.43) or MI (HR 0.84; 95% CI 0.69 to 1.03, p = 0.10). CONCLUSIONS: Sirolimus-eluting stents are superior to PES in terms of a significant reduction of the risk of reintervention and stent thrombosis. The risk of death was not significantly different between the 2 DES, but there was a trend toward a higher risk of MI with PES, especially after the first year from the procedure.
|
| 4 |
Review Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. 2007
Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schömig A, Pfisterer ME, Stone GW, Leon MB, de Lezo JS, Goy JJ, Park SJ, Sabaté M, Suttorp MJ, Kelbaek H, Spaulding C, Menichelli M, Vermeersch P, Dirksen MT, Cervinka P, Petronio AS, Nordmann AJ, Diem P, Meier B, Zwahlen M, Reichenbach S, Trelle S, Windecker S, Jüni P. · Institute of Social and Preventive Medicine, University of Bern, Bern, Switzerland. · Lancet. · Pubmed #17869634 No free full text.
Abstract: BACKGROUND: Whether the two drug-eluting stents approved by the US Food and Drug Administration-a sirolimus-eluting stent and a paclitaxel-eluting stent-are associated with increased risks of death, myocardial infarction, or stent thrombosis compared with bare-metal stents is uncertain. Our aim was to compare the safety and effectiveness of these stents. METHODS: We searched relevant sources from inception to March, 2007, and contacted investigators and manufacturers to identify randomised controlled trials in patients with coronary artery disease that compared drug-eluting with bare-metal stents, or that compared sirolimus-eluting stents head-to-head with paclitaxel-eluting stents. Safety outcomes included mortality, myocardial infarction, and definite stent thrombosis; the effectiveness outcome was target lesion revascularisation. We included 38 trials (18,023 patients) with a follow-up of up to 4 years. Trialists and manufacturers provided additional data on clinical outcomes for 29 trials. We did a network meta-analysis with a mixed-treatment comparison method to combine direct within-trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. FINDINGS: Mortality was similar in the three groups: hazard ratios (HR) were 1.00 (95% credibility interval 0.82-1.25) for sirolimus-eluting versus bare-metal stents, 1.03 (0.84-1.22) for paclitaxel-eluting versus bare-metal stents, and 0.96 (0.83-1.24) for sirolimus-eluting versus paclitaxel-eluting stents. Sirolimus-eluting stents were associated with the lowest risk of myocardial infarction (HR 0.81, 95% credibility interval 0.66-0.97, p=0.030 vs bare-metal stents; 0.83, 0.71-1.00, p=0.045 vs paclitaxel-eluting stents). There were no significant differences in the risk of definite stent thrombosis (0 days to 4 years). However, the risk of late definite stent thrombosis (>30 days) was increased with paclitaxel-eluting stents (HR 2.11, 95% credibility interval 1.19-4.23, p=0.017 vs bare-metal stents; 1.85, 1.02-3.85, p=0.041 vs sirolimus-eluting stents). The reduction in target lesion revascularisation seen with drug-eluting stents compared with bare-metal stents was more pronounced with sirolimus-eluting stents than with paclitaxel-eluting stents (0.70, 0.56-0.84; p=0.0021). INTERPRETATION: The risks of mortality associated with drug-eluting and bare-metal stents are similar. Sirolimus-eluting stents seem to be clinically better than bare-metal and paclitaxel-eluting stents.
|
| 5 |
Article Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. 2008
Windecker S, Serruys PW, Wandel S, Buszman P, Trznadel S, Linke A, Lenk K, Ischinger T, Klauss V, Eberli F, Corti R, Wijns W, Morice MC, di Mario C, Davies S, van Geuns RJ, Eerdmans P, van Es GA, Meier B, Jüni P. · Department of Cardiology, and CTU Bern, Bern University Hospital, Bern, Switzerland. · Lancet. · Pubmed #18765162 No free full text.
Abstract: BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.
|
|
|